Four card doors run from a browser
Plenty of office floors have the same four doors to control: main entry, server room, store and a back exit. One C3-400 Plus covers all four on a single Linux board, managed through eSSL BioCVSecurity 6.4.1 in a web browser.
Cards start at 30,000, and a licence takes that to 1,00,000. It keeps 5,00,000 transactions.
How many readers each door gets
Choose RS-485 readers and you can fit eight, so every door reads cards going in and coming out. Stick with 26-bit Wiegand and the limit is four, which means an entry reader plus an exit button on each door. Wiegand is also how a QR code reader for visitors gets connected.
- 12 inputs: exit device, door status and auxiliary for each door
- 8 Form C relays, four for locks and four auxiliary
- Alarm output for each door
- 9.6V to 14.4V DC; board 215.88 x 99.14 x 19.3 mm, wall mount
- 0 to 45 °C, 20% to 80% RH non-condensing
PC requirements and multi-panel rules
The software PC needs 16GB RAM and Windows 10 or later, with PostgreSQL as the default database and MS SQL or Oracle as alternatives. If you add more panels later, global anti-passback and global interlock let the rules follow people across all of them.