A door that locks again if nobody walks through
Someone presses the exit button, changes their mind, and the door sits unlocked. On this lock that can't last long: if the door isn't opened, the bolt locks again within 5 seconds. A door status output (NC/COM) also tells the controller or alarm whether the door is shut.
It is fail-safe, so it unlocks when power is cut. That's the right behaviour on an exit route, but it means a battery-backed supply if the door has to stay locked through a power cut. eSSL also lists an anti-tamper function.
Delay, current draw and plate sizes
Relock delay can be set to 0, 3 or 6 seconds and leaves the factory at 0. Size the power supply for the 950mA working current, not the 150mA static figure.
- Input 12VDC
- Face plate 207 x 35 x 41 mm
- Strike 95 x 25 x 2 mm
- Bolt 16 mm in diameter and 16 mm long